Biopotential readout circuits for portable acquisition systems
In recent years, we have witnessed a revolutionary change in biomedical signal monitoring. The traditional way of using bulky instruments is being replaced by portable and even wearable acquisition systems with wireless data transmission that will enable many non-clinical applications that rely on b...
Guardado en:
| Autores principales: | , , , |
|---|---|
| Formato: | Livre numérique |
| Lenguaje: | Anglais |
| Publicado: |
Dordrecht :
Springer Netherlands
2009.
Cham : Springer Nature |
| Colección: | Analog Circuits and Signal Processing
|
| Acceso en línea: | Accès sur la plateforme de l'éditeur Accès sur la plateforme Istex Accès Université d'Orléans Accès INSA CVL |
| Nota: |
Archives Springer e-books (Licence nationale) Archives Springer e-books (Licence nationale) |
| Autres localisations: | Voir dans le Sudoc |
| Edition sous un autre format: | • Biopotential Readout Circuits for Portable Acquisition Systems, Texte imprimé, 9781402090929 • Biopotential Readout Circuits for Portable Acquisition Systems, Texte imprimé, 9789048180707 • Biopotential Readout Circuits for Portable Acquisition Systems, Texte imprimé, 9781402091025 |
| LEADER | 03804nam a22003857a 4500 | ||
|---|---|---|---|
| 001 | 940949 | ||
| 008 | 090210s2009 xx ||| |||| 00| 0 eng d | ||
| 009 | PPN131117815 | ||
| 020 | |a 9781402090936 | ||
| 020 | |a 9781402090936 | ||
| 041 | 0 | |a eng | |
| 082 | |a 621.3815 | ||
| 100 | 1 | |a Yazıcıoğlu, Refet Fırat. | |
| 245 | 1 | 0 | |a Biopotential readout circuits for portable acquisition systems |c by Refet Fırat Yazıcıoğlu, Chris Hoof, Robert Puers ; edited by Mohammed Ismail. |
| 260 | |a Dordrecht : |b Springer Netherlands. | ||
| 260 | |a Cham : |b Springer Nature, |c 2009. | ||
| 490 | 0 | |a Analog Circuits and Signal Processing |x 2197-1854 | |
| 500 | |a Archives Springer e-books (Licence nationale) | ||
| 500 | |a Archives Springer e-books (Licence nationale) | ||
| 505 | 0 | |a to Biopotential Acquisition -- 24-Channel EEG Readout Front-End ASIC -- Biopotential Readout Front-End ASICs -- A Complete Biopotential Acquisition ASIC -- Wireless Biopotential Acquisition Systems -- Conclusions. | |
| 506 | |a Accès en ligne pour les établissements français bénéficiaires des licences nationales | ||
| 506 | |a Accès soumis à abonnement pour tout autre établissement | ||
| 506 | |a Conditions particulières de réutilisation pour les bénéficiaires des licences nationales. chttps://www.licencesnationales.fr/springer-nature-ebooks-contrat-licence-ln-2017 | ||
| 520 | |a In recent years, we have witnessed a revolutionary change in biomedical signal monitoring. The traditional way of using bulky instruments is being replaced by portable and even wearable acquisition systems with wireless data transmission that will enable many non-clinical applications that rely on biomedical signal monitoring. The main driver applications are early-warning systems, wellness, comfort and sports monitoring, brain-computer interfaces, gaming and entertainment. The common requirements from all these applications are miniature size, unobtrusiveness, high signal quality, and long-term power autonomy. This requires ultra-low-power and miniature SiP/SoC biomedical signal acquisition systems. Biopotential Readout Circuits for Portable Acquisition Systems describes one of the main building blocks of such miniaturized biomedical signal acquisition systems. The focus of this book is on the implementation of low-power and high-performance integrated circuit building blocks that can be used to extract biopotential signals from conventional biopotential electrodes. New instrumentation amplifier architectures are introduced and their design is described in detail. These amplifiers are used to implement complete acquisition demonstrator systems that are a stepping stone towards practical miniaturized and low-power systems. | ||
| 700 | 1 | |a Van Hoof, Chris. |4 aut | |
| 700 | 1 | |a Ismail, Mohammed. |4 aut | |
| 700 | 1 | |a Puers, Robert, |d 19..- |4 aut | |
| 776 | 0 | |t Biopotential Readout Circuits for Portable Acquisition Systems |b Texte imprimé |z 9781402090929 | |
| 776 | 0 | |t Biopotential Readout Circuits for Portable Acquisition Systems |b Texte imprimé |z 9789048180707 | |
| 776 | 0 | |t Biopotential Readout Circuits for Portable Acquisition Systems |b Texte imprimé |z 9781402091025 | |
| 856 | 4 | |q PDF |u https://doi.org/10.1007/978-1-4020-9093-6 |z Accès sur la plateforme de l'éditeur | |
| 856 | 4 | |u https://revue-sommaire.istex.fr/ark:/67375/8Q1-KLTXPTHS-8 |z Accès sur la plateforme Istex | |
| 856 | 4 | |5 452349901:747852170 |u https://ezproxy.univ-orleans.fr/login?url=https://dx.doi.org/10.1007/978-1-4020-9093-6 |z Accès Université d'Orléans | |
| 856 | 4 | |5 180339901:750869763 |u https://ezproxy.insa-cvl.fr/login?qurl=https://dx.doi.org/10.1007/978-1-4020-9093-6 |z Accès INSA CVL | |
| 997 | |0 940949 |1 Livre numérique |a Ressource numérique |b INSA |b ENSA |c 0/Bibliothèque numérique/ |c 1/Bibliothèque numérique/Autre ressource numérique/ | ||

