Omnidirectional inductive powering for biomedical implants
In the year 2000, a capsule endoscope was introduced on the market for diagnosis of small bowel diseases. This pill, about one centimeter in diameter, takes images of the gastric track and transmits them wirelessly to the outside world. Since the capsule is battery powered, the limited energy budget...
Αποθηκεύτηκε σε:
| Κύριοι συγγραφείς: | , |
|---|---|
| Μορφή: | Livre numérique |
| Γλώσσα: | Anglais |
| Έκδοση: |
Dordrecht :
Springer Netherlands
[20..].
Cham : Springer Nature |
| Έκδοση: | 1st ed. 2009. |
| Σειρά: | Analog Circuits and Signal Processing
|
| Διαθέσιμο Online: | Accès sur la plateforme de l'éditeur Accès sur la plateforme Istex Accès Université d'Orléans Accès INSA CVL |
| Σημείωση: |
Archives Springer e-books (Licence nationale) Archives Springer e-books (Licence nationale) |
| Autres localisations: | Voir dans le Sudoc |
| Edition sous un autre format: | • Omnidirectional Inductive Powering for Biomedical Implants, Texte imprimé, 9781402090745 • Omnidirectional Inductive Powering for Biomedical Implants, Texte imprimé, 9789048180622 • Omnidirectional Inductive Powering for Biomedical Implants, Texte imprimé, 9781402090813 • Omnidirectional Inductive Powering for Biomedical Implants, Texte imprimé, 9781402090745 • Omnidirectional Inductive Powering for Biomedical Implants, Texte imprimé, 9789048180622 • Omnidirectional Inductive Powering for Biomedical Implants, Texte imprimé, 9781402090813 • Omnidirectional Inductive Powering for Biomedical Implants, Texte imprimé, 9781402090745 |
| LEADER | 04214nam a22004217a 4500 | ||
|---|---|---|---|
| 001 | 940946 | ||
| 008 | 090210q2000 xx ||| |||| 00| 0 eng d | ||
| 009 | PPN131117785 | ||
| 020 | |a 9781402090752 | ||
| 020 | |a 9781402090752 | ||
| 041 | 0 | |a eng | |
| 082 | |a 621.3815 | ||
| 100 | 1 | |a Lenaerts, Bert. | |
| 245 | 1 | 0 | |a Omnidirectional inductive powering for biomedical implants |c by Bert Lenaerts, Robert Puers. |
| 250 | |a 1st ed. 2009. | ||
| 260 | |a Dordrecht : |b Springer Netherlands. | ||
| 260 | |a Cham : |b Springer Nature, |c [20..]. | ||
| 490 | 0 | |a Analog Circuits and Signal Processing |x 2197-1854 | |
| 500 | |a Archives Springer e-books (Licence nationale) | ||
| 500 | |a Archives Springer e-books (Licence nationale) | ||
| 505 | 1 | |a Magnetic Induction Inductive Link Design Power Converters and Voltage Regulators Omnidirectional Coupling Biological Tissue Interaction An Inductive Power Link for a Capsule Endoscope A Class E Driver for Deformable Coils Conclusions | |
| 506 | |a Accès en ligne pour les établissements français bénéficiaires des licences nationales | ||
| 506 | |a Accès soumis à abonnement pour tout autre établissement | ||
| 506 | |a Conditions particulières de réutilisation pour les bénéficiaires des licences nationales. https://www.licencesnationales.fr/springer-nature-ebooks-contrat-licence-ln-2017 | ||
| 520 | |a In the year 2000, a capsule endoscope was introduced on the market for diagnosis of small bowel diseases. This pill, about one centimeter in diameter, takes images of the gastric track and transmits them wirelessly to the outside world. Since the capsule is battery powered, the limited energy budget restricts both the amount and the quality of images that can be shot. To resolve this limitation, Omnidirectional Inductive Powering for Biomedical Implants investigates the feasibility of inductive powering for capsule endoscopy and freely moving systems in general. The main challenge is the random position and orientation of the power receiving system with respect to the emitting magnetic field. Where classic inductive powering assumes a predictable or fixed alignment of the respective coils, the remote system is now free to adopt just any orientation while still maintaining full power capabilities. Before elaborating on different approaches towards omnidirectional powering, the design and optimisation of a general inductive power link is discussed in all its aspects. Useful rectifier and inverter topologies are presented, including a class E driver that copes with coil deformations. Special attention is paid to the interaction of the inductive power link with the patient s body. Putting theory into practice, the implementation of an inductive power link for a capsule endoscope is included in a separate chapter | ||
| 700 | 1 | |a Puers, Robert, |d 19..- |4 aut | |
| 776 | 0 | |t Omnidirectional Inductive Powering for Biomedical Implants |b Texte imprimé |z 9781402090745 | |
| 776 | 0 | |t Omnidirectional Inductive Powering for Biomedical Implants |b Texte imprimé |z 9789048180622 | |
| 776 | 0 | |t Omnidirectional Inductive Powering for Biomedical Implants |b Texte imprimé |z 9781402090813 | |
| 776 | 0 | |t Omnidirectional Inductive Powering for Biomedical Implants |b Texte imprimé |z 9781402090745 | |
| 776 | 0 | |t Omnidirectional Inductive Powering for Biomedical Implants |b Texte imprimé |z 9789048180622 | |
| 776 | 0 | |t Omnidirectional Inductive Powering for Biomedical Implants |b Texte imprimé |z 9781402090813 | |
| 776 | 0 | |t Omnidirectional Inductive Powering for Biomedical Implants |b Texte imprimé |z 9781402090745 | |
| 856 | 4 | |q PDF |u https://doi.org/10.1007/978-1-4020-9075-2 |z Accès sur la plateforme de l'éditeur | |
| 856 | 4 | |u https://revue-sommaire.istex.fr/ark:/67375/8Q1-WK5048T8-K |z Accès sur la plateforme Istex | |
| 856 | 4 | |5 452349901:747852200 |u https://ezproxy.univ-orleans.fr/login?url=https://dx.doi.org/10.1007/978-1-4020-9075-2 |z Accès Université d'Orléans | |
| 856 | 4 | |5 180339901:750869798 |u https://ezproxy.insa-cvl.fr/login?qurl=https://dx.doi.org/10.1007/978-1-4020-9075-2 |z Accès INSA CVL | |
| 997 | |0 940946 |1 Livre numérique |a Ressource numérique |b INSA |b ENSA |c 0/Bibliothèque numérique/ |c 1/Bibliothèque numérique/Autre ressource numérique/ | ||

