La minisonde nucléaire "PIXE" et son application

CE TRAVAIL EST CONSACRE A LA MISE AU POINT DE L'ANALYSE PAR LA MINI-SONDE NUCLEAIRE PIXE ET SES APPLICATIONS. POUR LA FOCALISATION DU FAISCEAU, ON A UTILISE UN SYSTEME DE DEUX LENTILLES QUADRUPOLAIRES MAGNETIQUES. ON A PU DETERMINER, GRACE A UN DISPOSITIF EXPERIMENTAL LE COUPLE DE COURANTS D�...

Full beskrivning

Sparad:
Bibliografiska uppgifter
Huvudupphovsman: AZAHRA, MUSTAPHA
Övriga upphovsmän: Isabelle, Didier B., 1934-1995 (Directeur de thèse)
Materialtyp: Thèse et Mémoire papier
Språk:Français
Publicerad: [S.l.] : [s.n.] 1993.
Ämnen:
Anmärkning: 1993CLF21544
Autres localisations: Voir dans le Sudoc
Variante du titre:THE MINI-PROBE PIXE AND ITS APPLICATIONS
LEADER 02619nam a22002657a 4500
001 243838
008 990313s1993 xx|||||| |||| 00| 0 fre d
009 PPN044096925
041 0 |a fre  |b fre 
084 |a 001.B.20.I.30.K 
084 |a 530 
100 1 |a AZAHRA, MUSTAPHA. 
240 1 0 |a THE MINI-PROBE PIXE AND ITS APPLICATIONS 
245 1 0 |a La minisonde nucléaire "PIXE" et son application   |c Mustapha Azahra ; sous la direction de Didier Isabelle. 
260 |a [S.l.] :  |b [s.n.],  |c 1993. 
300 |a 5 P. 
500 |a 1993CLF21544 
502 |a Thèse de doctorat. Physique. Clermont-Ferrand 2. 1993 
504 |a 56 REF. 
520 |a CE TRAVAIL EST CONSACRE A LA MISE AU POINT DE L'ANALYSE PAR LA MINI-SONDE NUCLEAIRE PIXE ET SES APPLICATIONS. POUR LA FOCALISATION DU FAISCEAU, ON A UTILISE UN SYSTEME DE DEUX LENTILLES QUADRUPOLAIRES MAGNETIQUES. ON A PU DETERMINER, GRACE A UN DISPOSITIF EXPERIMENTAL LE COUPLE DE COURANTS D'EXCITATIONS I#C=3,68 A ET I#D=6,92 A QU'IL FAUT DONNER RESPECTIVEMENT A LA PREMIERE ET A LA DEUXIEME LENTILLE POUR AVOIR LA DOUBLE FOCALISATION. LA TACHE DU FAISCEAU DE PROTONS D'ENERGIE 3 MEV OBTENUE EST DE 20 M EN HORIZONTALE ET DE 40 M EN VERTICALE. L'ANALYSE DES SPECTRES PIXE A ETE REALISEE AVEC UN PROGRAMME DE DEPOUILLEMENT GUPIX. POUR DETERMINER LA CONCENTRATION DES ELEMENTS DE LA CIBLE AVEC UNE BONNE PRECISION, ON A FAIT UNE ETUDE DETAILLEE DES PARAMETRES EXPERIMENTAUX, EN PARTICULIER NOUS AVONS MIS AU POINT UN DISPOSITIF EXPERIMENTAL DOIGT TOURNANT PERMETTANT DE DETERMINER LA QUANTITE DE CHARGE AVEC UNE PRECISION INFERIEURE A 1%. L'EPAISSEUR DES FILTRES UTILISES ENTRE LA CIBLE ET LE DETECTEUR A ETE DETERMINEE AVEC UNE PRECISION DE 1%. LA METHODE DE CALIBRATION, POUR CONVERTIR L'AIRE DES PICS EN CONCENTRATION (PPM) NECESSITE QUE LE PARAMETRE DE CALIBRATION H SOIT DETERMINE EXPERIMENTALEMENT. EN UTILISANT DES ELEMENTS METALLIQUES PURS OU DES STANDARDS SYNTHETIQUES, ON A MONTRE QUE H EST CONSTANT. POUR VERIFIER L'EXACTITUDE DES PARAMETRES DETERMINES, ON A ANALYSE UN ECHANTILLON STANDARD DE VERRE NBS=610 CONTENANT 61 ELEMENTS ET DETERMINE LA CONCENTRATION DES ELEMENTS AVEC UNE JUSTESSE INFERIEURE A 10% 
650 |a Thèses et écrits académiques 
700 1 |a Isabelle, Didier B.,  |d 1934-1995.  |4 ths 
710 2 |a Université Blaise Pascal.  |4 dgg 
787 0 8 |i Reproduced as:  |0 246322659  |t La minisonde nucléaire "PIXE" et son application  |f Mustapha Azahra  |c Grenoble  |n Atelier national de reproduction des thèses  |d 1993  |p Microfiches  |s [Grenoble thèses] 
997 |0 243838  |1 Thèse et Mémoire papier  |a Ressource papier  |c 0/Orléans/  |c 1/Orléans/OSUC/  |z Orléans, OSUC, TH AZA-1993