MESURE DU NIVEAU D'UN LIQUIDE PAR ONDES ELASTIQUES GUIDEES : JAUGEUR A ECHOS-DETECTEUR DE PRESENCE A ABSORPTION
L'ETUDE COMPREND DEUX PARTIES. LA PREMIERE INTITULEE JAUGEUR A ECHOS A POUR OBJECTIF LA MESURE CONTINUE AU NIVEAU D'UN LIQUIDE. LE PRINCIPE CONSISTE A DETERMINER LE TEMPS DE PROPAGATION D'UN TRAIN D'ONDES GUIDEES QUI SE REFLECHIT A L'INTERFACE GUIDE-LIQUIDE. LE SCHEMA FONCTI...
Shranjeno v:
| Glavni avtor: | |
|---|---|
| Drugi avtorji: | |
| Format: | Thèse et Mémoire papier |
| Jezik: | Français |
| Izdano: |
[S.l.] :
[s.n.]
1989.
|
| Teme: | |
| Sporočilo: |
1989PA066304 |
| Autres localisations: | Voir dans le Sudoc |
| Variante du titre: | MEASUREMENT OF THE LEVEL OF A LIQUID BY GUIDED ACOUSTIC WAVES. GAUGE USING ECHOS: DETECTOR OF PRESENCE USING ABSORPTION |
| LEADER | 02726nam a22002897a 4500 | ||
|---|---|---|---|
| 001 | 233055 | ||
| 008 | 990313s1989 xx|||||| |||| 00| 0 fre d | ||
| 009 | PPN043957722 | ||
| 041 | 0 | |a fre |b fre | |
| 084 | |a 001.B.00.F | ||
| 084 | |a 530 | ||
| 100 | 1 | |a Legras, Olivier. | |
| 240 | 1 | 0 | |a MEASUREMENT OF THE LEVEL OF A LIQUID BY GUIDED ACOUSTIC WAVES. GAUGE USING ECHOS: DETECTOR OF PRESENCE USING ABSORPTION |
| 245 | 1 | 0 | |a MESURE DU NIVEAU D'UN LIQUIDE PAR ONDES ELASTIQUES GUIDEES : |b JAUGEUR A ECHOS-DETECTEUR DE PRESENCE A ABSORPTION |c OLIVIER LEGRAS ; SOUS LA DIRECTION DE EUGENE DIEULESAINT. |
| 260 | |a [S.l.] : |b [s.n.], |c 1989. | ||
| 300 | |c 30 cm. | ||
| 500 | |a 1989PA066304 | ||
| 502 | |a Thèse Doctorat. Physique. Paris 6. 1989 | ||
| 504 | |a 38 REF | ||
| 520 | |a L'ETUDE COMPREND DEUX PARTIES. LA PREMIERE INTITULEE JAUGEUR A ECHOS A POUR OBJECTIF LA MESURE CONTINUE AU NIVEAU D'UN LIQUIDE. LE PRINCIPE CONSISTE A DETERMINER LE TEMPS DE PROPAGATION D'UN TRAIN D'ONDES GUIDEES QUI SE REFLECHIT A L'INTERFACE GUIDE-LIQUIDE. LE SCHEMA FONCTIONNEL DU JAUGEUR MET EN RELIEF LES PRINCIPAUX ELEMENTS: GUIDE, TRANSDUCTEUR, ELECTRONIQUE DE MESURE. LES DIFFERENTS MODES DE PROPAGATION DANS LE GUIDE CHOISI: TUBE, SONT EXAMINES. LE MODE RETENU EST ANTISYMETRIQUE. LES MOYENS DE L'ENGENDRER (PIEZOELECTRICITE ET MAGNETOSTRICTION), DE L'OBSERVER (SONDE PIEZOELECTRIQUE, SONDE OPTIQUE), ET DE DETECTER L'ECHO PRODUIT PAR LA RUPTURE D'IMPEDANCE A L'INTERFACE SONT ANALYSES. UN JAUGEUR A TRANSDUCTEUR MAGNETOSTRICTIF A ETE REALISE A L'ECHELLE DU LABORATOIRE (COURSE: 2 ), RESOLUTION 1 MM). LA DEUXIEME PARTIE DETECTEUR DE LA PRESENCE D'UN LIQUIDE DECRIT DEUX METHODES POUR DECELER LA PRESENCE D'UN LIQUIDE A UN NIVEAU PREDETERMINE. ELLES SONT BASEES SUR L'ABSORPTION PAR LE LIQUIDE D'ONDES ELASTIQUES GUIDEES. LA PREMIERE METHODE EST MISE EN UVRE EN UTILISANT POUR GUIDE-LIGNE A RETARD UNE PARTIE DE LA PAROI DE LA CUVE ET EN FORMANT UNE BOUCLE GUIDE-AMPLIFICATEUR QUI CESSE D'OSCILLER EN PRESENCE DE LIQUIDE. LA DEUXIEME METHODE CONSISTE A REALISER UNE LIGNE A ECHOS: CETTE LIGNE EST UN GUIDE COMPOSITE DONT L'EXTREMITE SEULE EST SENSIBLE AU CONTACT DU LIQUIDE | ||
| 650 | |a Capteurs (technologie) | ||
| 650 | |a Ondes élastiques | ||
| 650 | |a Thèses et écrits académiques | ||
| 700 | 1 | |a Dieulesaint, Eugène. |4 ths | |
| 710 | 2 | |a Université Pierre et Marie Curie. |4 dgg | |
| 787 | 0 | 8 | |i Reproduced as: |0 246237627 |t MESURE DU NIVEAU D'UN LIQUIDE PAR ONDES ELASTIQUES GUIDEES |o JAUGEUR A ECHOS-DETECTEUR DE PRESENCE A ABSORPTION |f OLIVIER LEGRAS |c Grenoble |n Atelier national de reproduction des thèses |d 1989 |p Microfiches |s [Grenoble thèses] |
| 997 | |0 233055 |1 Thèse et Mémoire papier |a Ressource papier |c 0/Bourges/ |c 1/Bourges/BU/ |z Bourges, BU, BM1930 | ||