ETUDE DE LA PRECISION DES INTEGRALES EN RMN QUANTITATIVE

LA RESONANCE MAGNETIQUE NUCLEAIRE QUANTITATIVE SE PROPOSE DE DETERMINER L'AIRE DES SIGNAUX. CETTE QUANTITE EST PROPORTIONNELLE A LA CONCENTRATION DES NOYAUX RESONNANTS. DES EXPERIENCES DE RMN A 2 DIMENSIONS FOURNISSENT DES VOLUMES DE PICS QUI DEPENDENT DES DISTANCES INTERNUCLEAIRES (NOESY) OU D...

Cijeli opis

Spremljeno u:
Bibliografski detalji
Glavni autor: NADJARI, REZA
Daljnji autori: Grivet, Jean-Philippe (Savjetnik disertacije)
Format: Thèse et Mémoire papier
Jezik:Français
Izdano: [S.l.] : [s.n.] 1991.
Teme:
Bilješka: 1991ORLE2052
Autres localisations: Voir dans le Sudoc
Variante du titre:PRECISION OF INTEGRALS IN QUANTITATIVE NMR
LEADER 02802nam a22002657a 4500
001 196893
008 990313s1991 xx|||||| |||| 00| 0 fre d
009 PPN044193327
041 0 |a fre  |b fre 
084 |a 002.B.24.A.10 
084 |a 610 
100 1 |a NADJARI, REZA. 
240 1 0 |a PRECISION OF INTEGRALS IN QUANTITATIVE NMR 
245 1 0 |a ETUDE DE LA PRECISION DES INTEGRALES EN RMN QUANTITATIVE   |c REZA NADJARI ; SOUS LA DIRECTION DE JEAN-PHILIPPE GRIVET. 
260 |a [S.l.] :  |b [s.n.],  |c 1991. 
500 |a 1991ORLE2052 
502 |a Thèse Doctorat. Sciences médicales. Orléans. 1991 
504 |a 70 REF 
520 |a LA RESONANCE MAGNETIQUE NUCLEAIRE QUANTITATIVE SE PROPOSE DE DETERMINER L'AIRE DES SIGNAUX. CETTE QUANTITE EST PROPORTIONNELLE A LA CONCENTRATION DES NOYAUX RESONNANTS. DES EXPERIENCES DE RMN A 2 DIMENSIONS FOURNISSENT DES VOLUMES DE PICS QUI DEPENDENT DES DISTANCES INTERNUCLEAIRES (NOESY) OU DES CONSTANTES CINETIQUES D'ECHANGE CHIMIQUE (EXSY). LES DONNEES EXPERIMENTALES (SPECTRES 1D OU SURFACES 2D) SONT ENTACHEES D'ERREURS SYSTEMATIQUES (QUI AFFECTENT LA JUSTESSE DE LA MESURE) ET D'ERREURS ALEATOIRES OU BRUITS (QUI DIMINUENT LA PRECISION). DANS CE TRAVAIL, NOUS AVONS EXAMINE LA PRECISION DES MESURES D'AIRE OU DE VOLUME. NOUS CALCULONS DE DEUX MANIERES LA VARIANCE DE L'INTEGRALE, SOIT A PARTIR DE LA FONCTION D'AUTOCORRELATION DU BRUIT EN FREQUENCE, SOIT A PARTIR DE LA DENSITE SPECTRALE DU BRUIT TEMPOREL. LA PRECISION DE L'INTEGRALE DECROIT AVEC LA LARGEUR D'INTEGRATION ET DEPEND PEU DES FILTRES OU DES FONCTIONS D'APODISATION. NOUS DONNONS DES COURBES PERMETTANT DE PREVOIR LE RAPPORT SIGNAL/BRUIT NECESSAIRE POUR OBTENIR UNE PRECISION DONNEE. LES RESULTATS TROUVES EN RMN 1D PEUVENT ETRE FACILEMENT GENERALISES EN RMN 2D. NOUS MONTRONS QUE L'ECART-TYPE SUR LE VOLUME SE DECOMPOSE EN UN PRODUIT DE FACTEURS RELATIFS CHACUN A UNE DIMENSION DE FREQUENCE. LE FILTRAGE N'APPORTE QU'UNE AMELIORATION MODESTE DE LA PRECISION, AU DETRIMENT DE LA RESOLUTION. L'INTEGRATION NUMERIQUE DU SIGNAL APPARAIT COMME UNE METHODE PRECISE DE DETERMINATION DES AIRES, TRES COMPARABLE AU LISSAGE PAR MOINDRES CARRES, AUX METHODES DE PREDICTION LINEAIRE OU D'ENTROPIE MAXIMUM 
650 |a Thèses et écrits académiques 
700 1 |a Grivet, Jean-Philippe.  |4 ths 
710 2 |a Université d'Orléans.  |4 dgg 
787 0 8 |i Reproduced as:  |0 246384719  |t ETUDE DE LA PRECISION DES INTEGRALES EN RMN QUANTITATIVE  |f REZA NADJARI  |c Grenoble  |n Atelier national de reproduction des thèses  |d 1991  |p Microfiches  |s [Grenoble thèses] 
997 |0 196893  |1 Thèse et Mémoire papier  |a Ressource papier  |c 0/Orléans/  |c 1/Orléans/BU Sciences, Technologies, STAPS/  |z Orléans, BU Sciences, Technologies, STAPS, TS 19-1991-52  |z Orléans, BU Sciences, Technologies, STAPS, TS 19-1991-52 
999 |5 452342104:056981473  |a ORLEANS